High-precision metal component manufacturer

Consulting hotline

+086 0755-2708-8292 / 18938693455
Electroformed Sieve for Microfluidics
Release Date:2026-11-18

Electroformed Sieve for Microfluidics

Overview

A microfluidic sieve is a part nobody notices until it fails. It sits inline in a cartridge - at the inlet, ahead of a detection chamber, or around a packed bed of beads - and its job is to hold back what should not pass while letting everything else through at a predictable rate. The pore field sets both halves of that job. The cutoff is only as sharp as the pore size distribution, and the flow resistance is set by open area and by pore length. A field where most pores are right and a few are oversized still retains the bulk of the bead load, but it passes the occasional particle; a field with a burr on the upstream face sheds metal into a channel that may be far narrower downstream.

Electroforming builds the sieve from the pore outward. The pore field is defined as resist pillars on the plating surface; nickel grows in the open area between the pillars and closes into a continuous sheet at the target thickness, and when the resist is removed the pores are open through the sheet. Because the pore is a void left by a pillar and its wall is a plated surface, the pore can be given a taper and the wall comes out smooth. There is no blanking, no laser cut, no recut burr and no heat-affected zone at the rim. The sieve is one piece of nickel: no weave, no crossing wires, no adhesive or solder anywhere in the flow path, and one pattern defining every pore in the field.

Etching has a supporting role here too, and it is the mounting frame. A sieve thin enough to sit in a cartridge channel is too delicate to be handled, aligned and sealed on its own, so it is bonded into a frame that carries the seal land, the datum edges and the tab windows used during assembly. The frame is etched because it is thin, because the edge that meets a gasket must be free of burr, and because frame datums and sieve outline have to agree with the same artwork. The sieve itself is never etched. It is electroformed nickel, and the mounting frame is the only etched part in the set.

Uniformity is what a cartridge maker is really buying. A microfluidic device is often single-use and is usually closed before it is tested, so a pore field cannot be inspected once the unit is assembled; the confidence has to come from the lot. That means coupons cut from the panel and measured, pore images kept with the batch record, and a plating bath whose composition, pH, temperature and current density are logged run by run. When the bath drifts, the coupon shows it before the sieves reach the bonding station.

Parameter Window

  • Material: electroformed nickel, or nickel-cobalt alloy where a stronger sheet is required. The sieve is a single deposited metal, with no coating to flake into a channel. The mounting frame is nickel or SUS304/316L sheet.
  • Gauge: 0.03 mm to 2.0 mm across the family. Microfluidic sieves sit at the thin end; the frame is usually a little thicker, agreed at drawing review.
  • Pore geometry: round, square or slot pores are defined by the resist pattern; pore taper and land width follow the plating conditions agreed for the part.
  • Tolerance: quoted against the drawing, with the achievable figure depending on product structure - pore size, pitch, sheet thickness and open area all move it, so each part is confirmed at review.
  • Surface: matte or semi-bright as agreed. The sample-side face and the downstream face are specified separately, since only one of them sees the load.
  • Traceability: the lot code is etched into the mounting frame, not the sieve. A sieve at the thin end has no room for a legible mark, and a mark in the pore field would change the flow.

Manufacturing Process / Workflow (8 Steps)

  1. Drawing review. Engineers read the pore field, the open area, the frame datum scheme and the sealing land together, and flag any land too narrow to plate closed.
  2. Pattern generation. The pore field is written into photoresist as standing pillars on the plating surface, so pore position, shape and taper are fixed by artwork rather than by a beam path.
  3. Electrolyte preparation. Nickel sulfamate composition, pH, temperature, filtration and agitation are checked and recorded before the panel goes in.
  4. Electroforming. Current density and plating time are set to the sheet thickness target, and deposit thickness is checked on the panel as the run proceeds.
  5. Resist removal and release. The resist is dissolved out of the pores, the sheet is released from the plating surface, rinsed, dried and trimmed to the frame outline.
  6. Frame etching. The mounting frame is produced by photo chemical etching on a separate line: seal land, datum edges and tab windows are formed in one pass from the same artwork family as the sieve outline.
  7. Bonding and leak check. Sieve and frame are registered on the datum edges, bonded at the land, and the assembly is checked for flatness, pore field alignment and seal integrity.
  8. Inspection and packing. Pore coupons, thickness, open area, appearance and flatness are checked against the drawing; parts are tray-packed so the thin sheet is never stacked under load.

Core Advantages

  1. One pattern, one pore size. Every pore in the field comes from the same resist pattern, so the corner of the panel matches the centre and the cutoff does not vary across the flow path.
  2. A wall that is grown, not cut. No shear lip, no recast layer and no burr on either face, so the sieve does not shed metal into a channel downstream.
  3. A flat sheet with straight-through pores. Unlike a woven mesh there is no crimp, no crossing wire and no double thickness at an intersection, so open area and pore length are set by design rather than by weave.
  4. Thickness set by process, not by stock. Plating time and current set the sheet thickness, which fixes pore length and therefore the pressure drop across the sieve.
  5. The frame carries the seal. A sheet thin enough for a cartridge channel cannot be gripped or compressed against an O-ring on its own; the etched frame supplies the seal land, the datums and the stiffness.
  6. Single metal in the flow path. The sieve is nickel through its section, so there is no coating to lift at a pore rim and no dissimilar joint to corrode in the sample.

Typical Applications

  • Bead retention sieves in assay and digital PCR cartridges
  • Cell separation and enrichment modules
  • Plasma separation prefilters ahead of a detection chamber
  • Inline debris filters for lab-on-chip sample preparation
  • Support screens behind a polymer membrane stack
  • Etched mounting frames and sealing rings for sieve sets

Design Notes & Process Considerations

  1. State the cutoff as a distribution and a test method, not as a single number. What a cartridge actually experiences is a pore size band; naming the band and how it will be measured prevents a dispute at incoming inspection.
  2. Balance open area against flow resistance before fixing the pitch. More open area lowers pressure drop but narrows the land, and a land too narrow may not plate closed.
  3. Keep the land wide enough to plate. Very narrow lands plate thin at the top and can leave pinholes between pores that behave like oversized pores.
  4. Name which face sees the sample. The upstream face takes the load and the downstream face does not, and a drawing that says only "smooth" leaves the inspector to guess.
  5. Control the sealing land as a flatness item. A frame land that is not flat will not compress a gasket evenly, and a leak path around a sieve looks exactly like a sieve that passes particles.
  6. Do not use hardness as an acceptance item. What this process holds is pore geometry, sheet thickness, open area, surface condition and flatness; a hardness figure on the drawing cannot be held.
Consult Message