High-precision metal component manufacturer

Consulting hotline

+086 0755-2708-8292 / 18938693455
Electroformed Nickel Mesh for Medical Filtration
Release Date:2026-11-23

Electroformed Nickel Mesh for Medical Filtration

Overview

In a medical instrument the filter mesh is a quiet part. Fluid or gas passes through it, and the openings decide what goes through and what stays. Openings that match across the foil give a flow that a designer can predict. Openings that vary by a visible margin split the stream: some paths run free, others choke, and the same part behaves differently from one unit to the next. The rim of each opening matters as much as its size. A clean rim keeps the flow steady and holds the foil together through repeated rinse cycles; a torn rim frays and can shed metal into the path it was meant to clean.

The mesh is made by electroforming. Nickel is grown onto a flat substrate carrying a patterned resist, and the openings left in the resist become the openings in the foil. Metal arrives ion by ion, so each hole wall is the wall the resist defined and the rim closes as a grown edge, not a cut one. There is no punch, no shear band, no roll-over. Foil gauge follows plating time and current density, not the hole pattern. A fine array and a coarse one can be grown at the same thickness from the same bath, which is why opening size and foil strength are separate choices.

Photo chemical etching is present in this part number too, but only on the mounting ring. The ring holds the mesh in the housing: its outline, its seating step, its locating tabs, the aperture that exposes the active area and the flange that is welded or bonded. That ring is a flat part described by an outline and a step, so etching suits it. Etching does not form the mesh openings. A drawing that treats ring and mesh as one etched part ends up with tolerances that fit neither process.

What the process holds is worth stating at quotation. Hole geometry comes from the patterned substrate; gauge from plating; flatness from the flatness of the substrate and from low deposit stress. Hardness of electroformed nickel follows the bath chemistry and is not dialled to a figure the way a heat treatment would be. Repeatability comes from keeping the same patterned substrate and the same bath recipe, so the first foil of a repeat order grows to the same drawing as the first foil of the original order.

Parameter Window

  • Mesh material: electroformed nickel as the standard; nickel-cobalt alloy where the foil needs more strength or wear resistance. The mesh family is nickel-based only, with no copper, gold or silver.
  • Mounting ring material: SUS304, 304L and 316L for general corrosion resistance; titanium TA1 and TA2 for light weight or chloride exposure; copper C1100 for a conductive seat; aluminium 1060 and 5052 for low mass; kovar 4J29 where the ring is sealed into a glass or ceramic housing.
  • Gauge: mesh foil from 0.03 mm upward; mounting ring from 0.03 mm to 2.0 mm, the ring usually heavier than the foil it carries.
  • Hole pattern: hole size, pitch, array shape and open area are taken from the drawing; the wall is grown into the resist openings, so it follows the pattern rather than a bath dwell.
  • Tolerance: quoted against the drawing, with what is achievable depending on product structure - hole size, pitch, foil gauge and ring geometry all move it.
  • Edge and finish: hole rims free of burr, dross and torn metal, so the foil survives repeat cleaning; ring edges clean and step depth as drawn; cleaning and passivation to the drawing, glove handling, flat packing.

Manufacturing Process / Workflow (8 Steps)

  1. Application review. Medium, cleaning method, housing interface, target open area and retention need are read together, and a written reply sets out what the drawing asks against what the process holds.
  2. Drawing and pattern review. Hole array, open area, foil gauge, ring seat, datum and the joint between mesh and ring are checked together; a mesh dimension and a ring dimension are not quoted to the same tolerance band.
  3. Patterned substrate preparation. Photoresist is applied to a flat substrate and patterned so the hole array exists as openings in the resist; substrate flatness is verified before plating, because the foil will inherit it.
  4. Nickel electroforming. Bath chemistry, temperature, current density and plating time are set for the required foil gauge; nickel grows into the resist openings until the deposit reaches thickness, and deposit stress is kept low so the foil does not curl when released.
  5. Separation and cleaning. The foil is separated from the substrate, rinsed in stages, cleaned and dried flat; the released foil is checked for curl before it moves on.
  6. Mounting ring etching. The ring is produced by photo chemical etching: outline, seating step by controlled half-etch, locating tabs and weld flange come from one artwork, and the aperture is opened in the same run.
  7. Assembly and inspection. Mesh and ring are joined as drawn; hole size, pitch, open area, foil flatness, rim condition and ring step are measured, and a rinse or flow check is run on the assembly where the application calls for it.
  8. Packing and handover. Parts are handled with gloves, packed flat and interleaved, and shipped with the lot record and a retained coupon so a repeat order can be compared with this one.

Core Advantages

  1. Openings grown, not cut. The rim of each hole is a grown edge, with no shear band, no roll-over and no burr to fray during cleaning or break the flow unevenly.
  2. Straight hole walls. Because the deposit follows the resist wall upward from the substrate, the opening does not waist in the middle the way a two-sided etch through thin foil can.
  3. Even openings across the foil. Hole size and pitch come from one patterned substrate, so the array stays consistent from the centre to the edge and the flow stays even over the whole active area.
  4. Flatness from the substrate. The foil is grown on a flat surface and released, so the plane it leaves with is the plane of the substrate rather than the result of a straightening step; it seats in the housing without gaps.
  5. Repeat cleaning without deformation. A grown rim does not fray and low deposit stress keeps the foil flat, so the mesh can be rinsed and reused through many cycles without losing its opening shape.
  6. Ring and mesh on one datum. The ring is etched from the same drawing set as the mesh pattern, so seat, tabs and active area line up when the two are joined, and a stored pattern keeps repeat lots comparable.

Typical Applications

  • Filtration screens in fluid lines of medical instruments
  • Intake meshes on sampling and analytical devices
  • Reusable filter discs in rinsable filtration modules
  • Screens in gas and air handling paths of medical equipment
  • Mesh elements in suction and collection canisters
  • Micro screens in compact fluid handling assemblies

Design Notes & Process Considerations

  1. State the medium and the cleaning method. A part that is rinsed often needs a clean grown rim and a flat foil; the answer moves the pattern and the finish more than any tolerance call does.
  2. Keep open area in proportion to foil gauge. A narrow opening in a thick deposit closes before the foil reaches thickness, so a deep, tight array is a plating question rather than a drawing question.
  3. Say how the ring and the mesh are joined. A weld flange needs width; an adhesive joint needs a flat land and a bond area; a crimped seat needs a step. The ring drawing follows that answer.
  4. Ask for released flatness together with the measuring method. Flatness of the foil is set by the substrate and by deposit stress, and a number without a method cannot be checked at either end.
  5. Treat nickel hardness as a bath property. Electroformed nickel hardness follows the bath chemistry and is not dialled to a specification on request, so ask what the bath delivers before writing a hardness figure into the drawing.
  6. Keep the mesh and the ring on separate drawings. One is grown, one is etched; combining them into a single sheet invites tolerances that suit neither process.
Consult Message
TOP